<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">故障一:油泵啟動后,低壓斷路開關(guān)跳閘
<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">此類故障需要以下檢查:
1<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、檢查電源的缺相現(xiàn)象。
2<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、檢查高壓濾芯是否嚴重阻塞,導致油泵電機電流太大。
3<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、檢查低壓斷路開關(guān)是否設(shè)定太小。
<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">故障二:開機后,回參考點時找不到參考點
1<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、由于光柵尺的讀數(shù)頭連接部位是否松脫,導致機器在回程時,讀數(shù)頭不能與光柵尺的參考點重合而此時油缸的行程已用完,油泵處于工作負載狀態(tài)。如是這一原因,則需要按下數(shù)控系統(tǒng)的紅色停止鍵,停止回參考點,重新連接校正好光柵尺的連接板,再進入手動模式工作狀態(tài)下,使滑塊手動向下,讓滑塊與下模重合時再進入手動或半自動模式工作狀態(tài),重新回參考點,排除故障。
2<span style="font-family: 宋體; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、機器在上次操作完畢后,由于操作人員未嚴格按照操作關(guān)機,將機器斷電前把滑塊停在上死點位置,而在下次開機時,未將滑塊手動向下,放置上下模重合后的位置,而進行回參考點操作,引起該次操作不能找回參考點,如果是這一原因,則需要將系統(tǒng)轉(zhuǎn)為手動狀態(tài),手動模式將滑塊下行*、下模重合位置,再進入半自動或自動模式狀態(tài)下,重新找回參考點。